Note:

The star energy label, issued by the Ministry of Industry and Trade of Vietnam, shows the consumers, level of air conditioner's energy efficiency.

FTKC Series

Smile Curve Series

The FTKC series features Daikin's smile curve design for the front panel creates a stylish, modern appearance which blends easily with any interior décor.

  • Improved performance over non-inverter models
  • Titanium apatite photocatalytic air-purifying filter
  • Quiet nights in your neighborhood

Features

Smile Curve

The FTKC series features Daikin's smile curve design for the front panel. The smile curve creates a stylish, modern appearance which blends easily with any interior decor.

Next-Generation Refrigerant R-32

To cope with climate change, Daikin has now adopted 
R-32, next-generation refrigerant which does not deplete the ozone layer and lower global warming.

Energy Saving

After the indoor temperature approaches the set temperature, inverter control adjusts to low capacity operation to maintain this temperature, making inverter models more energy saving than non-inverter models.

Powerful

Inverter air conditioners operate at maximum capacity as soon as they start up. This burst of increased power allows them to reach the set temperature more quickly.

Comfortable

Inverter air conditioners adjust capacity according to changes in the air conditioning load and the difference between the indoor temperature and set temperature is small, giving higher comfort levels than with non-inverter air conditione

Titanium Apatite Photocatalytic Air-Purifying Filter

While the filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs odours and allergens, as well as deodorises odours. This filter delivers consistent performance for approximately three years if it is washed with water once every six months.

Intelligent Eye

Detect human movement in a room by using infrared sensor to prevent energy wastage.

Smart Controller (optional)

The whole series give you a choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoors Unit Quiet Operation, which decreases the sound pressure level 3 to 6 dB (A) below the Low setting and help you to sleep comfortably at night..

Anticorrosion Treatment of Outdoor Heat Exchanger Fins

The surface of heat exchanger fins is covered with a thin acrylic resin layer to enhance the fins' resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets.

Indoor Unit Quiet Operation

The whole series give you a choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoors Unit Quiet Operation, which decreases the sound pressure level 3 to 6 dB (A) below the Low setting and help you to sleep comfortably at night..

Specifications

Model Name Indoor Unit FTKC25RVMV FTKC35RVMV FTKC50RVMV FTKC60RVMV FTKC71RVMV
Outdoor Unit RKC25RVMV RKC35RVMV RKC50RVMV RKC60RVMV RKC71RVMV
Capacity Rated (Min.-Max.) kW 2.5 (1.0-3.4) 3.5 (1.3-4.1) 5.2 (1.4-6.0) 6.0 (1.4-6.7) 7.1 (2.1-7.5)
Btu/h 8,500 (3,400-11,600) 11,900 (4,400-14,000) 17,700 (4,800-20,500) 20,500 (4,800-22,900) 24,200 (7,200-25,600)
Power Consumption Rated W 680 (210-1,100) 960 (250-1,455) 1,365 (260-1,730) 1,740 (300-2,060) 2,365 (400-2,550)
CSPF [tooltip] 5.35 5.50 6.05 5.82 5.75
Energy Efficiency Level [tooltip] ★★★★★ ★★★★★ ★★★★★ ★★★★★ ★★★★★
Indoor Unit FTKC25QVMV FTKC35QVMV FTKC50QVMV FTKC60QVMV FTKC71QVMV
Sound Pressure Levels H/L/SL dB(A) 38/25/19 39/26/22 44/35/29 45/36/30 46/37/31
Dimensions H x W x D mm 283 x 770 x 223 295 x 990 x 263
Outdoor Unit RKC25QVMV RKC35QVMV RKC50QVMV RKC25QVMV RKC25QVMV
Sound Pressure Levels H/SL dB(A) 47/44 49/45 49/43 50/43 51/46
Dimensions H x W x D mm 550 x 658 x 275 595 x 845 x 300
Note: The above values are based on operation with a 220 V, 50 Hz power supply.

Measurement conditions

1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Back to top